Professional Supplier of Laboratory Scientific Instruments
Professional Supplier of Laboratory Scientific Instruments
LPA-177W Wet-method fully automatic laser granulometry particle size analyzer is a high-performance wet-method fully automatic laser particle size distribution analyzer developed by Shuoboda after years of technical accumulation. It is designed according to GB/T19077-2016 ISO13320 and other standards, Mie scattering and diffraction principles, advanced red and blue dual light source optical system and 128-level multi-detector three-dimensional detection system, which realizes the reception of scattered signals in the full angle range, expands the full range test to a higher resolution, and fully detects the subtle differences in the details of each particle level.
It adopts a fully sealed metal shell and a multi-system integrated design. It has the advantages of strong anti-electromagnetic interference ability, wide range, good repeatability, high precision, high degree of automation, and fast test speed. It adopts ultrasonic anti-dry burning technology. The ultrasonic wave will automatically disconnect the power supply when the sample pool is in a waterless state. It has an intelligent module design and humanized operation software to quickly obtain accurate and reliable particle size results. It is very suitable for enterprises and scientific research units with a wide range of products and a wide distribution range. It is a domestically produced, cost-effective, fully automatic laser particle size analyzer that is widely praised by customers.
Particle size distribution test of solid powder and emulsion slurry in various industries such as scientific research institutions, electronic materials, powder coatings, papermaking, chemicals, ceramics, building materials, manganese carbonate, pesticides, pigments, medicines, water-coal slurry, cosmetics, abrasives, food, calcium carbonate, talcum powder, kaolin, alumina, rare earth, catalysts, foaming agents, refractory materials, cement, graphite, marine sediments, etc.
Model | LPA-177W |
Measuring range | 0.01µm~3000µm |
Sample detection pool | 60mm×60mm High-quality quartz glass |
Sample dispersion pool | Volume 500mL, material: 304 all-stainless steel |
Dispersion method | 60w ultrasonic disperser |
Detector | 128-level multi-element detector |
Laser life | More than 70,000 hours |
Communication interface | RS232 standard serial data transmission method |
Sample dosage | Milligrams~grams/time |
Test principle | Static scattered light full-scale Mie scattering theory |
Injection method | Wet injection |
Repeatability error | ≤1% (national standard material D50 deviation) |
Accuracy error | ≤1% (national standard material D50 deviation) |
Optical path system | Inverted Fourier optical system |
Signal light source | Imported semiconductor laser |
Fully automatic test | Automatic water absorption, centering, measurement, cleaning, drainage |
Test medium | Tap water, distilled water or ethanol, etc. |
Instrument volume | Length 740×width 360×height 530 (mm) |
Instrument weight | About: 60kg |
Working power supply | AC220V ±22V 50Hz ±0.5Hz: |
Environmental requirements | Temperature: 5℃~35℃; Humidity: <85%; |
1. The inverted Fourier optical system is adopted to greatly reduce the stray light generated by multiple reflections of the sample pool and the optical mirror. The large-angle scattered light is not limited by the lens aperture, which effectively improves the test resolution and ensures the accuracy of the test data.
2. 128-level multi-element detector completes the reception of forward, side and backward scattered signals. The scattered signal detection is fine and the detection resolution is high.
Each level of the detector background light is independently compensated, and the highest gain is achieved. The signal is collected and amplified at a high speed, the dynamic response is sensitive and fast, and the optical path center self-check is completed at the same time.
3. Imported semiconductor laser, dual light source test resolution is higher, the main light source wavelength is 650nm, 30mw, and the life is >70000h. The auxiliary light source wavelength is 405nm, 20mw, and the auxiliary light source enhances the resolution of the small particle size range.
4. The high-rigidity optical structure of the elastic support and the stable optical path ensure that the instrument is in a stable state for a long time.
5. The sample detection optical dish is made of high-quality high-optical glass glue to ensure optical accuracy and mechanical strength.
Integrated design, no need to disassemble
The instrument adopts an integrated design with a simple appearance. The circulation sampling system is inside the instrument. You only need to add samples to the sample pool to automatically complete the test. The large-diameter ultrasonic dispersion pool and the stirrer mix evenly and quickly, so that the sample is fully dispersed and the bubbles are discharged quickly. The peristaltic pump circulates for short distances to avoid sample stratification. The peristaltic pump directly squeezes the pipeline to transport the liquid, which is highly efficient. All pipelines are of equal cross-section and flow rate, without centrifugal negative pressure area, with little contamination to the sample and easy cleaning. There are no bubbles during transportation. The accuracy and repeatability of the instrument test are guaranteed.
Perfect preparation system
It has intelligent functions such as automatic water absorption, automatic centering, automatic testing, automatic cleaning, and ultrasonic anti-dry burning. The unique fully automatic sample mechanical stirring motor device can fully disperse the sample while reducing bubbles and liquid splashing, ensuring stable and reliable test results.
Stable dispersion system
The standard sample pool with a volume of 500ml is made of 304 stainless steel, which is durable and corrosion-resistant. Built-in automatic water suction pump, water can be automatically added without manual operation. A water level detector is installed above the sample pool. When the water level reaches the specified height, the electromagnetic valve automatically closes to ensure the accuracy of each test medium. Because dispersion and circulation are completely independent, the cycle test time is short, which reduces the sample's adhesion, contamination and wear on the optical test dish, and improves and extends the service life.
1. The Chinese and English operating systems are interchangeable with one key, the software interface is clear and easy to operate.
2. The report output has three formats: free distribution, normal distribution, and RR distribution. The content includes cumulative particle size distribution data and curves, interval particle size distribution data and histograms, typical particle size values such as D3, D10, D25, D50, D75, D84, D90, D97, volume average particle size, area average particle size, specific surface area and other data.
3. The test data can be viewed online, printed or converted to PDF format for storage.
4. RS232 and USB standard serial data transmission methods are adopted.
5. The analysis software is compatible with Windows XP/Win7/Win10 systems.
Experienced service team and strong production support team provide client worry-free order service.
If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.
Contact Us