Shuoboda's commitment to innovation and practice in HPLC instrument in the last two decades,we have launched ournew flagship high-performance liquid chromatographic system 800 to the market.The 800 is an integratedUHPLC/HPLC instrument (with ultra-high-efficiency and ultra-performance configurations),it provides flexibility toaccomplish testing range from separation power for complex samples with speed or to daily analysis.
Infusion System: | Linear motor digital-driven pump |
Flow range: | 0.001 - 5mL/min, n0.001mL/min increments |
Maximum operating pressure: | 120MPa (corresponding 17000psi) |
Flow precision: | ≤0.06%RSD |
Flow accuracy: | ≤+0.3% |
Compression compensation: | Automatic, continuous, selectable solvent type |
Post-column cleaning: | Automatic post-column cleaning function, which can control the cleaning flow rate |
Gradient setting range: | 0-100% |
Extended application: | Record number of times the plunger rod seal is used |
Infusion System: | Type I Reciprocating infusion pumps Type Il Linear motor digital-driven pump |
Flow range: | 62MPa 0.001-10 mL/min, n0.001mL/min increments 90MPa 0.001-5mL/min, n0.001mL/min increments |
Maximum operating pressure: | 62MPa(corresponding 9000psi), 90MPa(corresponding 13000psi) |
Flow precision: | ≤0.06%RSD |
Flow accuracy: | ≤+0.3% |
Compression compensation: | Automatic, continuous, selectable solvent type |
Post-column cleaning: | Automatic post-column cleaning function, which can control the cleaning flow rate |
Gradient setting range: | 0-100% |
Extended application: | Record number of times the plunger rod seal is used |
Infusion System: | Linear motor digital-driven pump |
Flow range: | Type l: 0.001-5.0mL/min in steps of 0.001 Type Il: 0.001-10.0mL/min in steps of 0.001 |
Maximum operating pressure: | 70MPa (corresponding 10150psi) |
Flow precision: | ≤0.06%RSD |
Flow accuracy: | ≤+0.3% |
Compression compensation: | Automatic, continuous, selectable solvent type |
Post-column cleaning: | Automatic post-column cleaning function, which can control the cleaning flow rate |
Gradient setting range: | 0-100% |
Online degassing: | Degassing channel Systec AF |
Degassing chamber: | 480µl |
Extended application: | record the number of times the plunger rod seal is used |
Experienced service team and strong production support team provide client worry-free order service.
If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.