Professional Supplier of Laboratory Scientific Instruments
Professional Supplier of Laboratory Scientific Instruments

DA-3000A Semi-automatic TLD Reader is a highly reliable and cost-effective thermoluminescent reader that can effectively measure the radiation dose absorbed by the thermoluminescent material contained in the dose box.
The reader is integrated with an automatic sample introduction/ejection system, which can automatically read up to 120 dosage elements in one load, supporting multi-batch continuous measurement.
The system software integrates a result database, so operators can easily manage measurement data in various formats and generate measurement reports in specific formats.
| physical parameters | |
| size and weight | 345*240*270mm; weight about 25kg |
| shell material | Sheet metal shell, spray-coated or anodized |
| Environment | -20℃~60℃, humility 10%~60% |
| Power supply | 220VAC/50Hz |
| operating parameters | |
| Operation mode | Single sample testing |
| Detection method | Automatic continuous reading |
| interactive mode | Photomultiplier tube detection, analog signal amplification processing |
| maintenance mode | Equipped with touch screen human-machine interface and application software for simultaneous dual-work operation |
| Adapted dose tablets | With self-diagnosis function; modular design facilitates quick replacement on site |
| measuring ray | γ, β, X, neutron rays |
| Heating unit parameters | |
| Heating method | Electrode heating, linear temperature rise, maximum temperature 500℃ |
| Get temperature | Room temperature ~500℃ can be set arbitrarily |
| pre-heat temperature | Room temperature ~500℃ can be set arbitrarily |
| Heating rate | 0℃/s~50℃/s can be set arbitrarily |
| Temperature control accuracy | ±1% |
| Measurement unit parameters | |
| measurement method | Photomultiplier tube (PMT), analog signal amplification 109 levels |
| High voltage supply | High voltage 0~1200V adjustable, high voltage stability: ±0.005% |
| Detection unit cooling | Semiconductor plus controlled refrigeration, the refrigeration temperature can be set |
| Measuring range | 0.1μSv~12Sv; up to 300Sv (sensitized magnesium titanium sheet) |
| Measurement resolution | Under laboratory conditions, it can reach 0.1μSv after sufficient preheating. |
| Measurement stability | 10 consecutive measurements after sufficient preheating, RSD≤1% |
| dark current | After preheating, multiple continuous readings RSD≤1% |
| Reference light | After preheating, multiple continuous readings RSD≤1% |

Experienced service team and strong production support team provide client worry-free order service.
If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.
Contact Us