The TOC-800ELaboratory Total Organic Carbon (TOC) Analyzer for liquids and solids uses the high-temperature catalytic oxidation-NDIR detection principle to measure the total organic carbon concentration in water samples. It can detect water samples with TOC concentrations from 0.050ppm to 35000.0ppm. It has high sensitivity, accuracy and good stability.
TOC-800E total organic carbon analyzer is an instrument with simple structure. The main components are installed on the host computer. Before measurement, the instrument needs to connect the gas line and prepare reagents. The instrument is controlled by special software installed on an embedded microcomputer or an external computer to perform data processing such as measurement, calibration, and printing.
The sample is fully burned and decomposed into carbon dioxide and water by the high-performance oxidation catalyst in the combustion furnace. The water vapor is removed after being cooled by the condenser. The carbon dioxide is measured by a non-dispersive infrared detector (NDIR) to determine the total organic carbon in the sample. The content measured; the inorganic carbon in the sample is decomposed into carbon dioxide and water by an acid reagent, and the water vapor is removed after being cooled by a condenser, and the carbon dioxide is measured with a non-dispersive infrared detector (NDIR), thereby determining the content of the total inorganic carbon TIC in the sample: Total organic carbon TOC=TC-TIC.
International standard ISO8245;
National environmental protection standard HJ501-2009 of the People's Republic of China;
National Metrology Verification Regulations of the People's Republic of China JJG 821-2005
TOC-800E total organic carbon analyzer | |
Test items | TC、IC、TOC、NPOC |
Measuring principle | High temperature oxidation-NDIR detection principle |
TOC detection range | 0.050~35000mg/L |
TOC detection accuracy | 0.050mg/L |
Salt tolerance | 100g/L |
Furnace temperature | 1300℃ |
TOC accuracy error | ≤±5% |
Sample volume | 20~1000µl |
Analysis time | 3~8min |
repeatability error | ≤3% |
Zero drift | ±2%/D |
Range drift | ±2%/D |
Test Conditions | Acid Reagent: Phosphoric Acid Solution Carrier gas: high-purity oxygen (≥99.999%) |
Ambient temperature | 0-60℃ (temperature change within ±5℃/d) |
Relative humidity | ≤90%RH |
Power supply | 220V AC≤±10% 50Hz |
Power | 800W |
Size | 60cm×46cm×49cm |
Weight | 50kg |
Software meets GMP computer system verification:
Electronic signature
1) Log in through username and password, which are unique.
2) Passwords have length requirements to improve security.
3) It has a manual screen lock function to ensure the uniqueness and safety of the operation.
Permission management
1) Multi-level permission settings.
2) Administrators can grant different permissions to other operators to ensure that personnel only have permissions equivalent to their job functions.
Data integrity
1) It has an audit trail function and cannot be turned off.
2) All test results are saved and cannot be modified or deleted.
3) All operations are recorded (as long as the person entering has traces).
4) If the detection method is modified, the modified parameters will be recorded.
5) Data can be exported for backup to protect stored data for future calls.
Create a new user interface: Administrators can grant different permissions to other operators to ensure that personnel only have permissions equivalent to their job functions. | |
Testing interface: The detection curve is visible in real time, which is more intuitiveAutomatic average calculation | |
Curve fitting interface: Automatically fit curves, calculate formulas, and tie them to corresponding methods.You can also manually add records and fit curves. | |
Audit trail: 1) Cannot be closed. 2) All operations are recorded (as long as the person entering has traces). |
Name | Description | Origin |
The electromagnetic valve | 200kpa diameter 1.6mm | Japan |
Peristaltic pump | 60ml/min reduction DC motor | China |
Thermostat | Accuracy: 0.1℃; Electric shock life: 1*105 times; | China |
Micropump | Usage environment: 0-50℃ ≤85% | USA |
Dryer | Delivery volume: 20μl per time; Accuracy: 1%; | USA |
Burner | Diaphragm material: PEEK | China |
NDIR | 0-1000ml/min | Germany |
Item Name | Specification | Unit |
quartz wool | 1-3μm | g |
Platinum alumina catalyst | Platinum content 0.5% | g |
Combustion tube | / | pc |
Halogen removal pipe | / | pc |
quartz plate | 15g | bag |
filter | / | ea |
O-ring | / | pc |
vial | 100ml | ea |
acid bottle | 100ml | ea |
PTFE connector | 6 to 3 | ea |
Injection nut | PEEK | ea |
Air line nut | PTFE | ea |
Thumb screws | M5 | ea |
Connecting pipe | 3.2*1.6mm | meter |
power cable | / | pc |
software | V1.0 | set |
User manual | / | pc |
Certificate | / | pc |