SHUOBODA adheres to the consistent development concept of high-performance liquid chromatograph instruments, and on the basis of further understanding user needs and usage habits, from the perspective of user convenience, has dedicated itself to creating a new product that is close to laboratory life.
Column oven
Heating method: semiconductor heating/cooling.
Temperature: lower than ambient temp. 5 to 80℃.
Temperature accuracy/stability: ±0. 5 /0.05℃.
Temperature ramp speed: in 15min from 20 to 50℃.
Temperature cool-down speed: in 15min from ambient temp to
txt, csv, AIA/cdf, pdf format compatible to link with MS office,
LIMIS and third party CDS for data transfer.
GLP/FDA CRF21 PART 11 compliance including privilege
management, log management and audit tracking.
IQ/CQ module is available, including OQ/PV and software IQ/OQ
confirmation.
ASTM baseline noise and drift automatic tracked and calculated
ELSD
Substances without UV absorption can be detected, and samples that are less volatile than the mobile phase can be detected without the need for samples with chromophoric groups. The light absorption characteristics of the sample is not required, and can solve the problem of HPLC detection, such as phospholipids, sugars, underivatized fatty acids and amino acids.
The high-performance probing system consisting of a laser and a photomultiplier tube provides higher detection sensitivity. Low-temperature evaporative light scattering detector also adapts to the requirements of high-temperature evaporation conditions, providing customers with more conditions to choose from.
Optimize the internal structure and circuit design, effectively reduce the noise and electromagnetic interference of the instrument, and improve the resolution and comprehensive performance of the product.
Function humanization, alarm function.
Advantages
Excellent performance, cost-effective.
Strong customer base.
Application program support and perfect after-sales serviceAny sample with less volatility than the mobile phase can bedetected.
Low temperature atomization and evaporation in the mobilephase, with high sensitivity to thermally unstable and highlyvolatile compounds
Wide gradient and solvent compatibility with no solvent peakinterference.
Auxiliary carrier gas improves detection sensitivity, ensuringcleanliness in the detection tank and avoiding pollution.
High-precision temperature control ensures the accuracy ofthe detection.
Atomized structure is easy to disassemble and installexpediently to clean.
Temperature, flow, signal gain and other parameters, fullyrealize the software intelligent full reverse control, in confor-mity with relevant regulations