GR Series Thermoluminescence TLD Chips Detector

Product introduction


GR series lithium fluoride thermoluminescence detectors are passive solid integral detectors. It is characterized by small size (high spatial resolution), effective atomic number close to air and human tissue, free from electromagnetic radiation interference, wide measurement range, low measurable lower limit, good reproducibility, and high dose rate pulse measurement characteristics of the radiation field. They can be applied to personal monitoring of ionizing radiation, environmental monitoring, and measurement of specific radiation fields (including the differential measurement of n and γ mixed fields). It can also be used in radiology, radiation biology, reactor engineering, archaeology and other disciplines.

Thermoluminescence Detector Technical Parameters

ItemSpecification
Detection objectX, γ-ray; Material: LiF: Mg, Cu, P or LiF: Mg, Ti optional
Detection objectNeutron rays; Material: 6LiF: Mg, Cu, P or 6LiF: Mg, Ti optional
ShapeDisc (also square, powder, square rod optional)
Specificationsφ4.5×0.80mm (other specifications can be customized)
Energy response(photons from 30KeV to 3MeV): <20%
Relative sensitivity62 times (TLD-100)
Linear range100nGy~12Gy
Detection threshold0.1μGy
Dispersion≤± 5%, 3%, 1% (optional)
Response to neutronsResponse to absorbed dose due to heavy particles is LET dependent, which favors the difference of gamma components in n, gamma mixed fields
StabilityThere is no obvious decline after one month of storage at room temperature, and about 3% decline after one month of storage at 50°C
Illumination effectThere is no obvious response to indoor scattered sunlight, incandescent light, and fluorescent lamp; there is a response to direct sunlight (ultraviolet light)
Working environmentT<50%; RH<90%

Specification

Thermoluminescence detector
No.ModelTypeSpecificationUnit
1GR-200ALiF(Mg,Cu,P)ф4.5×0.80mm (1%)piece
2GR-200ALiF(Mg,Cu,P)ф4.5×0.80mm (2%)piece
3GR-200ALiF(Mg,Cu,P)ф4.5×0.80mm (3%)piece
4GR-200ALiF(Mg,Cu,P)ф4.5×0.80mm (5%)piece
5GR-200ALiF(Mg,Cu,P)ф3.6×0.40mm (2%)piece
6GR-200ALiF(Mg,Cu,P)ф3.6×0.60mm (2%)piece
7GR-200ALiF(Mg,Cu,P)ф3.6×0.80mm (2%)piece
8GR-200LiF(Mg,Cu,P)4.0×4.0×0.89mmpiece
9GR-200LiF(Mg,Cu,P)3.2×3.2×0.89mmpiece
10GR-200LiF(Mg,Cu,P)3.0×3.0×0.89mmpiece
11GR207A7LiF(Mg,Cu,P)ф4.5×0.80mmpiece
12GR2077LiF(Mg,Cu,P)4.0×4.0×0.80mmpiece
13GR2077LiF(Mg,Cu,P)3.2×3.2×0.20mmpiece
14GR2077LiF(Mg,Cu,P)3.2×3.2×0.40mmpiece
15GR2077LiF(Mg,Cu,P)3.2×3.2×0.60mmpiece
16GR2077LiF(Mg,Cu,P)3.2×3.2×0.80mmpiece
17GR206A6LiF(Mg,Cu,P)ф4.5×0.80mmpiece
18GR-200FLiF(Mg,Cu,P)Film 4.0×4.0mmpiece
19GR-200F7LiF(Mg,Cu,P)Film 5.0×5.0mmpiece
20GR-200FLiF(Mg,Cu,P)Film ф4.5×0.20mmpiece
21GR-200RLiF(Mg,Cu,P)0.1×0.1×0.6mmea
22GR-200RLiF(Mg,Cu,P)1.0×1.0×1.0mmea
23GR-200R7LiF(Mg,Cu,P)1.0×1.0×6.0mmea
24GR-100MLiF(Mg,Ti)5.0×5.0×0.80mmpiece
25GR-100MLiF(Mg,Ti)4.0×4.0×0.80mmpiece
26GR-100LiF(Mg,Ti)ф4.5×0.80mmpiece
27GR-100MLiF(Mg,Ti)ф4.5×0.80mmpiece
28chemically pure powder80~200 meshg
29Analytical Pure Powder80~200 meshg
30lead room100*100*100mmset