Professional Supplier of Laboratory Scientific Instruments
Professional Supplier of Laboratory Scientific Instruments
1. The GC912 series can only be equipped with a single commonly used detector (except FPD).
2. LCD screen display, full microcomputer control system, a single computer can control up to 253 chromatographs, with 7-channel temperature control system and 8-channel external event time program.
3. The instrument uses an RJ45 network cable output interface, which makes control and acquisition simple and convenient, and can realize remote control of the instrument and remote data transmission, processing and supervision. Can be connected to unit supervisors and superior supervisors to facilitate supervision by supervisors.
4. The instrument has a built-in chromatography workstation, which has functions such as intelligent peak identification/automatic processing, multi-channel spectrum integration and exchange processing, etc.
5. The column oven has an automatic rear door opening for rapid cooling, and can carry out 8-step program temperature rise. The column oven has a near room temperature control function (5℃ above room temperature).
6. It can be configured with packed column injector, capillary column injector, gas valve injection, ballast reforming furnace and other devices.
7. It has a fault self-diagnosis function, which can display the fault location and nature at any time. It has an over-temperature protection function. When the temperature exceeds the set temperature, it will automatically stop the force. Heat and alarm.
Thermal conductivity detector | Hydrogen flame detector | Electron capture detector | Flame photometric detector | ||
TCD | HTCD | FID | ECD | FPD | |
Sensitivity (detection limit) | ≥3500 mV.ml/mg(benzene) | ≥10000 mV.ml/mg(benzene) | ≤1pg/s (n-C16) | ≤10fg/ml(γ-666) | ≤1.0 pg/s(P) ≤10 pg/s(S) |
baseline noise | ≤5μv | ≤10μv | ≤5 μv | ≤20 μv | ≤20 μv |
Baseline drift | ≤30μv/30min | ≤50μv/30min | ≤50μv/30min | ≤50μv/30min | |
linear range | >105 | >107 | >104 | >104(P)>103(S) | |
stable schedule | ≤1h | ≤30min | ≤30min | ≤30min |
Number of temperature control interfaces: 7 channels
Temperature control range: room temperature +5℃~400℃
Temperature control accuracy/stability: ≤0.5%
Display accuracy: 0.1℃
Programmed temperature rise:
Programmed temperature rise steps: 8 steps
Programmed heating rate: 0~39.9°C/min (adjustment increment 0.1C/min)
Repeatability of programmed temperature rise: ≤0.5%
3. Number of external event interfaces: 8 channels
4. Column box volume: 110x210x210mm (depth x width x height)
5. Host size: 320x405 x370mm (length x width x height)
6. Instrument weight: ≤20kg
7. Power: about 1200W