Professional Supplier of Laboratory Scientific Instruments

Differential thermal analyzer

DTA-3332A RT~1150℃ Differential Thermal Analyzer

Contact Us
  • Fast And Safe Logistics
  • Get samples for free

RT~1150℃ Differential Thermal Analyzer

DTA3332 High temperature differential thermal analyzer has been granted the National Patent.

Product introduction

Differential thermal analysis is a technology that measures the temperature difference and temperature relationship between a substance and a reference substance under program-controlled temperature. The differential thermal analysis curve describes the relationship between the temperature (ΔT) between the sample and the reference material as a function of temperature or time.

Working principle

In DTA tests, changes in sample temperature are caused by endothermic or exothermic effects of phase transitions or reactions. Such as: phase transition, melting, transformation of crystal structure, boiling, sublimation, evaporation, dehydrogenation reaction, fragmentation or decomposition reaction, oxidation or reduction reaction, destruction of lattice structure and other chemical reactions.

Features

Differential Thermal Analyzer Technical parameters

ModelDTA-3332A
Temperature rangeRoom temperature~1150℃
Measuring range0~±2000μV(expandable)
DTA sensitivity0.01μV
DTA accuracy0.1μV
Heating rate1~100℃/min
Temperature resolution0.01℃
Temperature accuracy±0.1℃
Temperature repeatability±0.1℃
Temperature controlHeating: program control, parameter can be adjusted as required; Constant temperature: program control, constant temperature time can be set arbitrarily
Furnace structureThe upper cover opening structure is adopted, with high precision and easy operation
Atmosphere controlInternal program automatic control
Data interfaceStandard USB interface, supporting data cable and operating software
Display method24bit color, 7-inch LCD touch screen display
Parameter standardEquipped with standards, with one-key calibration function, users can calibrate the temperature by themselves
Baseline adjustmentUsers can adjust the baseline through the slope and intercept of the baseline
Power supplyAC 220V 50Hz (110V 60Hz is optional)

Free sample test

R&D Laboratory

On-site training & technical guidence

Exhibition product disply

Adequete supply