Professional Supplier of Laboratory Scientific Instruments
Professional Supplier of Laboratory Scientific Instruments
RV-NDJ-1D Asphalt Brookfield Rotational Viscometer is designed and made as per T 0625-2011 “Asphalt Brookfield Rotational Viscosity Test (Brookfield Viscometer Methods)” in the Industry standard of People’s Republic of China JTG E20-2011Specifications and Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering.
It is suitable to determine the absolute viscosity of Newtonian liquids and the apparent viscosity of Non-Newtonian liquids. It is widely used for determining viscosities of asphalt, hot melt adhesive, paraffin, high polymer, and other liquids.
1. The instrument adopts advanced mechanical design technology and manufacturing process, using micro-computer technology to control speed, collect data and process data. Accurate data acquisition, high sensitivity, reliable test results, easy to use, and good looking.
2. Display selection of white backlight, high brightness LCD display, can directly display the viscosity of the sample, the number of the rotor, speed and other information, data display clear.
3. The test data can show on the screen real time and also output by printer. In addition, the instrument can also connect with PC via RS232 communication port.
4. Choose different models can have different ranges, for measuring different samples.
1. Measurement range: 100 mPa•s ~ 2×106 mPa•s (If you select the No.30 spindle, the measurement range can be extended to 4×105 mPa•s)
2. Rotor Specifications: No.21, 27, 28 and 29 total 4 pieces of spindles (the No.30 spindle is optional)
3. Rotor speed: (5, 10, 20, 50)r/min
4. Measurement error: ±1% (F•S); (If you select the No.30 spindle, it will be ±3% (F•S)
5. Temperature control range: 45 °C ~ 200 °C
6. Temperature control accuracy: ±0.1 °C
7. Sample cylinder: 20 ml
8. Print output: Needle printer
9. Communication with the PC: RS232 interface
10. Power supply: AC 220V±10%, 50 Hz
11. Ambient temperature: 5 °C ~ 35 °C (when the controlling temperature is close to ambient temperature, please run the air conditioner to let the ambient temperature be 5 °C lower than the controlling temperature)
12. Relative humidity: ≤80%
Experienced service team and strong production support team provide client worry-free order service.
If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.
Contact Us