Professional Supplier of Laboratory Scientific Instruments
Professional Supplier of Laboratory Scientific Instruments
• In the fields of nuclear environment monitoring, radiobiology and nuclear medicine, the specific activity of measured samples in most cases is lower than 40Bq/kg, which is the same order of magnitude as the specific activity of trace natural radionuclides in the surrounding environment soil. In this case, it is necessary to reduce the background of the system, including the environmental background from cosmic rays and the background caused by the Compton effect. The low-background anti-Compton gamma spectrometer is based on solving this problem.
• Low-background high-purity germanium inverse-Compton gamma spectrometer mainly consists of the following parts: HPGe main detector, anti-coincidence shielding detector composed of NaI ring detector and NaI plug detector, lead shielding room, electronics Anti-coincidence circuit, multi-channel analyzer, spectrum analysis software. computers and printers etc.
• When high-energy radiation (such as primary cosmic rays) penetrates the main detector and the anti-coincidence shielding detector, and both detectors have signal output, the anti-coincidence electronics circuit behind will prevent these signals from being recorded by the spectrometer, thereby Play the role of suppressing or shielding the background signal. Similarly, when the gamma rays emitted by the sample to be measured are incident on the main detector, the photons that have the Compton effect will generate a non-all-energy peak signal, and at the same time, they will be scattered at the same time and enter the anti-coincidence shielding detector to generate a signal , the following anti-coincidence electronics circuit will prevent these signals from being recorded by the spectrometer, thereby suppressing the Compton effect and improving the peak-to-compton ratio.
Item | Specification |
Detector | Standard configuration is N-type HPGe (GMX) 60% relative efficiency detector |
NaI Ring and Coincidence Detector | 9”x9” NaI ring, 3.5” ID. 10.75” OD. 6”x2” NaI Pie Detector. Resolution: @662 keV ≤7%. |
Maximum sample size | 3.5" diameter, 3" height (capacities up to 750 mL). |
Electronics | DSPEC-502A Digital Dual MCA, 556H High Voltage Module |
Shield | Thick low background lead chamber with Tn/Cu composite shielding design on the inner layer. Optional anti-cosmic ray components, (plastic scintillator detector) |
Software | GammaVision Gamma Spectroscopy Software. |
Peak Compi | 1300:1 or better (with a standard GMX60 detector). |
Background count rate | 0.5 cps or less with box or cylindrical factory shields. |
Experienced service team and strong production support team provide client worry-free order service.
If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.
Contact Us