DA-2000D Thermoluminescence Dosimeter Reader

Product introduction

DA-2000D thermoluminescence dosimeter reader can measure the thermoluminescence detector (hereinafter referred to as the detector) after being irradiated by X, γ, β, neutron and other rays, and give the readout value and dose value. , with functions such as automatic calibration, background subtraction, heating parameter setting and printing. The thermoluminescent dose reader can be connected to a computer, and data management and printing can be performed through the application software of the thermoluminescent dose reader. Conforms to the national standard of the People's Republic of China GB 10264-88 "Thermoluminescence dosimetry system for personal and environmental monitoring". DA-2000D thermoluminescent dose reader adopts 7-inch color touch screen, which has clear display and easy operation.

Features

• 7-inch touch screen, full Chinese color display, built-in printer, easy for users to operate, operate and maintain;

• The high voltage part has three modes: automatic, locked, fixed;

• The heating plate can be replaced, which is convenient for the measurement of thermoluminescence detectors of different shapes and specifications;

• The database supports a variety of query functions such as unit name, personal name, gender, dose box barcode, date of measurement, tested personnel, untested personnel, etc.;

• Power-on automatic drying function, suitable for instruments with humid environment and low frequency of use;

• An attenuation filter can be placed to expand the dose measurement range.

• With PC software, barcode scanner interface; stand-alone storage of 1000 pieces of measurement data.

• Support scanning code entry, form export, and personal database filing.

Thermoluminescence Dosimeter Reader Technical parameters

Light measurement system
Dose test rangeLiF: Mg, Ti: 10-5Gy ~ 1Gy LiF: Mg, Cu, P: 10-7Gy ~ 10Gy LiF: Mg, Ti-M: 0~100Gy
Measuring items HeatingX, gamma, beta, neutron
System stability≤0.2%
Measurement and reading time40s (can be customized)
Coefficient of variation of sensitivity repeatability≤0.1%±0.05%/℃
Drawer light leakage≤0.1% of internal light source
Background value≤300
High voltage0~1500V
Power supplyAC 220V±10%, 50Hz
Heating system 
Heating temp. rangeRoom temperature~400℃
Temperature repeatability≤1%
Heating temperature deviation≤±2℃
Heating time0~500s
Heating time repeatability≤0.1%
Heating rate1~40℃·s-1
Use conditions
Working environmentIndoor
Working temperature10~40℃