Portable octane analyzer is used for instant octane rating of motor gasoline, corresponding to motor and research methods (RON and MON) as well as for cetane number of diesel fuels. In addition for an inquiries, temperature rating of the analyzed liquid and diesel fuel solidification is provided. The results of measuring are displayed on the LCD.

The operational principle of the Octane Meter lies in gasoline octane rating and diesel fuel cetane rating based on the analysis of change of properties of an dielectric permeability and electromagnetic induction.

Octane analyzer has the portable compact design and is used for on-line inspection of motor fuel quality in the field and laboratory conditions. The operating conditions of the Octane analyzer usage: ambient temperature from –10C to +30C, relative humidity 80% at 25 C, atmosphere pressure 84-106kPa. The device gets power from DC elements of type AA (supply voltage 6V). 

ParameterDescriptionAccording
Measurement of octane level.Research (RON), motor (MON) method. Anti Knocking Index AKI (Pump octane number PON).ASTM D 2699-86, ASTM D 2700-86.
Measurement of cetane level.Simultaneously with cetane number the type and temperature of hardening of diesel fuel is defined.ASTM D 4737-03, ASTM D 613, EN ISO 5165.
Measurement freezing-point of diesel fuel.It is defined depending on cetane numbers of diesel fuel.Facultative parameter.
Measurement type of diesel fuel.Type of diesel fuel. (S-summer, W-winter, A-arctic) is defined depending on temperature of hardening.Facultative parameter.
Parameter descriptionValue
Types of controlled fuelall types of gasoline
Range of measured octane level40-120
Range of measured cetane level20-100
Measurement inaccuracy of octane number0,5
Measurement inaccuracy of cetane number1
Data displaydigital
Time of measurement, secbelow 10
Consumption current, mA30
Time of continuous running with one set of batteries, hour100
Operation temperature range-100С…+40 0С
Relative humidity, %30…..80
Atmosphere pressure, kPascal64…..106
Dimension, mm: sensor;electronic module  60 х 100 211 x 100 x 45
Weight, gr680
Mean-time-between-failures, hour>1000