Professional Supplier of Laboratory Scientific Instruments

Closed Cup Flash Point Tester

ASTM D93 PMCC Pensky-Martens Flash Point Tester

Contact Us
  • Fast And Safe Logistics
  • Get samples for free

BD-D93-261 PMCC Pensky-Martens Flash Point Tester is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester.

It is used to make determination of the closed cup flash point of the petroleum products.

  1. This instrument is designed as per GB/T261 and ASTM D93.
  2. The heating power is continuously adjustable. The power is shown visually by voltmeter. The temperature control mode is advanced and reasonable.
  3. The structure is designed small and exquisite. The stainless-steel table board is beautiful and easy to clean.
  4. Operation is easy. Test results are precise. It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.
ModelBD-D93-261
Power supply AC (220±10%)V, 50Hz.
Heating device The heating power is continuously adjustable from 0 W to 600W.
Heating rate (1 ~ 12)°C/min; Controllable and adjustable.
Stirring rate  Procedure A: (90 ~ 120)RPM Procedure B: (250±10)RPM
Oil cupInner diameter 50.7mm ~ 50.8mm.
Depth 55.7mm ~ 56.0mm 
The scribed line depth of capacity of testing oil 33.9mm ~ 34.3mm.
Capacity of testing oil about 70ml
Igniting deviceIgniting source gas (or other civilian fuels, the same below)
Electric ignition. Gas flame diameter3.2mm ~ 4.8mm
ThermometersMercury-in-glass thermometer. Specifications are as below
 (1)Scale -5°C ~ 110°C, division 0.5°C
 (2)Scale 20°C ~ 150°C, division 1°C
  (3)Scale 90°C ~ 370°C, division 2°C
Ambient temperature ≤ 35°C
Relative humidity ≤ 85%
Maximum power consumption 650W
Dimensions (m) 0.42*0.35*0.35
No.ItemUnitQtyRemarks
1Thermometer -5 ~ 110 °C, each scale division is 0.5 °CPiece1GB / T261-2008 Standard requirement
2Thermometer 20 ~ 150 °C, each scale division is 1.0 °CPiece1
3Thermometer 90 ~ 370 °C, each scale division is 2 °CPiece1
4Driving flexible shaftPiece1 
5Latex tube Ф3 250mmPiece3One for alternate
65A fuse (Ф5 × 20)Piece2 
7Thermometer adapterSet1 
8Thermometer liner (Cut suitable length of liner to wrap the lower end of the thermometer, so that the thermometer is just inserted into the thermometer adaptor)Piece5 
Get in Touch With Us

Experienced service team and strong production support team provide client worry-free order service.

    Need help? Contact us.

    If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.

    Contact Us