Professional Supplier of Laboratory Scientific Instruments

ICP-OES/ICP-AES Spectrometers

Inductively Coupled Plasma Emission Spectrometer

Contact Us
  • Fast And Safe Logistics
  • Get samples for free

Working principle: ICP spectrometer operating principle drawing

  1. Excellent optical systems, advanced control system: to ensure accurate positioning, good signal-to-background ratio
  2. Imported key components: ensure instrument accuracy and sensitivity;
  3. Minimum Matrix effect: 99% of the sample without matrix separation;
  4. Wide measuring range: analysis from Ultra micro to constant;
  5. Multiple elements analysis: 72 kinds of metal elements and some non-metallic elements can be analyzed,;
  6. Can do qualitative or quantitative analysis;
  7. Convenient analysis software: Based on the Windows XP platform ,the third generation of Chinese or English operating software, making it easier to operate easily, without having to install, software can be used directly, the data processing system to provide a variety of functions, output data can be arbitrarily selected and print.
Independent research and develop software with company logoIncrease the standard addition method
Based on windows XP, windows7 windows8, the third-generation multi-window analysis software in English and ChineseIntegral ways: single-point fast, multi-point average, Gaussian curve
multi-window and multitask can do simultaneouslyTest methods are: routine testing, normalization, coefficient calculation, standard addition method
Default best analysis mode (no need modification or writting by the analysts), rapid scanning speed, support for laser printers, arbitrarily select the analysis result needed print, and can be printed at the same time.More user friendly (arranged by analysis step -from left to right - from top to bottom)
Note: ICP as a large precision inorganic analytical instrument, its software operation and hardware of the instrument itself are the same important. The software without company logo is the earliest one , cannot be upgraded ,the operation speed is the slowest and few function. It is the theft of my company's software.
Circuit TypeSelf-excited oscillation inductance feedback circuitOutput Power800--1200W
working frequency40.68MHz ± 0.05%Output power stability≤0.3%
Frequency Stability<0.1%Leakage of electromagnetic fields emitted intensity30cm at E<1V / m
Output working coilAn inner diameter of 25mm, 3 turns
TorchesThree concentric outer diameters of 20mm quartz torch
Coaxial sprayerouter diameter 6mm, special requirements can be customized
Binocular-type spray chamberAn outer diameter 34mm, special requirements can be customized
Observation positionvertical
Plasma gas flow meterAuxiliary gas flow meterThe gas carrier flow meterThe carrier gas regulator valveCooling water
(100-1000)L/h    (1.6-16L/min)(1-100)L/h      (0.16-1.66L/min(10-100)L/h      (0.16-1.66L/min)0-0.4Mpa)L/h  Water temperature:15-25℃ gas flow>5L/min water pressure>0.1Mpa cooling water:Resistivity>1MΩ
Light pathCzerny-TurnerScan Step0.0004nm
focal length1000mmExit, entrance slit20μm×25μm
Grating SpecificationsIon etching holographic gratingGroove density of 3600 lines / mm, groove area: 80 × 110mm (or groove density)Reflector Specifications (optional specifications)(78×105×16)mm
 2400 lines / mm, groove area: 80 × 110mm)lensφ30,1:1 imaging
Reciprocal linear dispersion rate0.26nm/mmReflector SpecificationsConcave

Resolution≤0.006nmFull bandSplitter thermostat26℃±1℃
Scan wavelength range180-500nm,3600 Line / mm  
180-800nm,2400 Line / mm  
Photomultiplier tube specificationsR212UH or R928Sampling circuit  The use of foreign high-precision operational amplifier, the instrument sensitivity and accuracy greatly improved  
Photomultiplier tube negative high voltage0-1000V, automatic adjustment, the stability of <0.05%Instruments data acquisition  Connected to the computer via serial port, thereby simplifying the circuit to make connection easier  
Photomultiplier tube current measuring range10-12 ~ 10-4 A specifications optionalMetering method  Single and multi-element sequential measurement, single-pass scan  
Signal acquisition of V / F exchange1mV corresponds to 100Hz  

The manufacturer with most foreign customers (Russia, Vietnam, Mexico, South Africa, Zimbabwe, the United Arab Emirates), almost domestic testing institutions also choose our instruments (including: the 389 plant of 6th Aerospace Institute , Shenzhen Tyco testing Ltd., Academy of Architectural Sciences of Shenzhen, Guangzhou Building materials Research Institute, Inner Mongolia metallurgical Research Institute, China Institute of Agricultural Sciences, etc.), as well as some famous universities (Tsinghua University, Jiangxi University of Science, Xiamen Chemical Engineering, , Changsha Normal University and so on.

Starting from 2000, based on French JY company technology, specializing in the production ICP spectrometer. Having a group of professionals who engaged in the ICP spectrometer at the earliest in domestic, guaranteed by their rich working experience and enthusiasm, and improve services we are dedicated to provide high-precision, sensitivity and good stability of the plasma emission spectrometer product.

ItemInstrument NameDetailsQtyUnit
1HostICP-8100 Inductively Coupled Plasma Emission Spectrometer Host1set
  Czerny-Turner Ion e tched holographic grating1set
stepping motor1set
Photomultiplier tube PMT1set
electronic control system1set
Inductance feedback self-excited oscillation circuit1set
RF generator1set
atomizer2pcs
Spray chamber2pcs
Torque tube2pcs
Scanning spectrometer1set
Gas controller1set
Cooling air flow meter1pcs
Auxiliary gas flow meter1pcs
Carrier gas flow meter1pcs
Incident slit1set
Exit slit1set
Optical path control device1set
Main power cable1pcs
Main power socket1pcs
Sample operation platform1set
Flame observation window1set
Flame regulator1set
High-frequency power1set
Power protector1set
Optical path protection gas1set
2Constant temperature systemYT-1800 Intelligent temperature control cooling circulating water tank1set
Circulating water pump1set
Circulating water tank air conditioner1set
3Analysis softwareICP analysis software1set
Analytical methods: a complete set of methods
used by the unit
  
Analysis mode: software default optimal analysis mode, with the instrument diagnosis, spectrum analysis and several measurement methods and several kinds of integration mode, the unit is optional  
4ComputerLenovo Qitian M71501set
Display: 19 inch LCD1set
Other: sound card, network card, DVD CD-ROM1set
5PrinterHP1007Laser Printer1set
6Exhaust systemAxial flow fan1set
Get in Touch With Us

Experienced service team and strong production support team provide client worry-free order service.

    Need help? Contact us.

    If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.

    Contact Us