Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
Fully automated wavelength scanning and peak searching.
Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flame out.
Deuterium lamp and self-absorption background regulation.
Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
Measuring method: flame absorption method and emission method.
Result printing: parameter printing, data result printing and diagram printing.
Complete automatic control system:
With the help of the software, the following can be easily achieved
Selection of the element lamp
Up-down-front-rear adjustment of the lifter
Adjustment of the optical energySelection of the slitDetermination of wavelength scanning and peak searchingSelection of the atomizer
Setting of the background deduction methodControlling of the gas flowAutomatic flaming and flaming out
Setting of the graphite furnace testing method
Advanced graphite furnace temperature control technology:
The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process.
The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data. The fast-heating capacity can improve the flexibility of the elements furthe
Use the ordinary power source of 220V without need of dynamic power of 380VThe maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samplesThree grades adjustable gas flow can accustom to more application needs
Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error
Safe, reliable and convenient flame system:
EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily.
Efficient atomization system enables a higher sensitivity
The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit tempering. Thus, it keeps the operation people and equipment from harm and damage.
Multifunctional software workstation:
A workstation that is supported WINDOWS 7The rich menu brings great convenience to the use of customer. Convenient conversion between different menus makes the operation more easily
Various analytical correction methods provide the users more choices
Basic fault parameter settings enable even the beginners can do the normal operation. Flexible storage, editing and printing methods give the user largest support
Technical specifications:
Model
AAS-4530F
Monochromator type:
Czerny-Turner
Grating
1800 lines/mm
Grating blaze wavelength
250nm
Wavelength Range
190-900nm
Spectrum Bandwidth
0.1nm/0.2nm/0.4nm/1.0nm/2.0nm automatic switching
Wavelength Accuracy
±0.15nm
Wavelength Receptivity
≤0.04nm
Absorbance range
-0.1-2.000A
Baseline stability
±0.005Abs/30min(Cu)
Characteristic viscosity
0.02μg/ml/1% (Cu)
Detection limit
0.004μg/ml (Cu)
Spectral bandwidth deviation
≤0.2nm±0.02nm (bandwidth 0.2nm, Cu)
Measurement repeatability
≤0.5% (flame method, Cu)
Lamp stand
8
Burner
full metal titanium burner
Sprayer
high-efficiency glass atomizer
Spray chamber
explosion-proof pre-mixed
Power supply
220V±22V, 50Hz±1Hz, 200W
Host size
700mmX550mmX530mm
Net weight
80kg
Flame System
Acetylene air burner
100mm
Ignition dynamic baseline drift
≤0.006Abs/30 min
(Cu) Characteristic viscosity
0.025μg/ml/1%
Related standard accuracy deviation
≤0.5%(Cu, absorbance>0.8A)(detection limit Cu ≤0.008μg/ml)
Safety system
when pressure is insufficient, the system automatically cut off the gas and power off, flame out and unconformity of the burner
Graphite Furnace
Temperature upper limit
3000℃
Largest temperature rise speed
≥2000℃/second
Characteristic quantity
Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy
Cu≤3% Cd≤3%
Safety system
Over current protection /Low air pressure alarm / protection Low cooling water flow alarm/protection
Size and weight
550mm×450mm×300mm, 65Kg
software:
Applicable to Windows 7 XP 2000 NT
Instrument self-test function
Password setting function
In the method establishment function, the instrument parameters, calibration curve and slope readjustment parameters, and flame atomizer parameters can be set.
Standard Accessory:
PC workstation
HP inkjet printer
Oil free Air compressor
Acetylene reducing valve
Cu Hollow cathode lamp
Air filter
Optional Accessory:
Graphite furnace system
Graphite furnace autosampler
Cooling water circulation machine
Hydride generator
Hollow cathode lamps of various elements
Product details:
Application
Customer site
Factory view
Get in Touch With Us
Experienced service team and strong production support team provide client worry-free order service.