Professional Supplier of Laboratory Scientific Instruments

Medical & Nuclear Emergency

IBA MagicMax Universal X-ray Evaluation Output System

Suitable for evaluating various X-ray machines, including: CT machines, film machines, fluoroscopy machines, pulse fluoroscopy, portable X-ray machines, etc. One-time exposure measurement data including kVp, PPV, dose, dose rate, exposure time, HVL, total filtration. Free data storage and analysis software is provided randomly, and user reports can be customized.
Contact Us
  • Fast And Safe Logistics
  • Get samples for free

IBA MagicMax Universal X-ray Evaluation Output System

Product introduction           

• Suitable for evaluating various X-ray machines, including: CT machines, film machines, fluoroscopy machines, pulse fluoroscopy, portable X-ray machines, etc.

• One-time exposure measurement data including kVp, PPV, dose, dose rate, exposure time, HVL, total filtration.

• Free data storage and analysis software is provided randomly, and user reports can be customized.

Features

• With an external dual-channel detector interface, a second-channel dose detector can be attached at the same time.

• Data transmission application direct wired connection, high-speed data transmission technology. Can truly achieve 0.1ms detection technology.

• The dose and kVp waveform can be displayed in real time for easy analysis. The minimum resolution time of the wave form is 0.1 milliseconds.

Range and accuracy of conventional X-ray machines and fluoroscopy systems

• Kilovolt: 40-150kV / ±2%

• Dose: 50nGy-50Gy / ±5%

• Dose rate: 0.1µGy/s-120mGy/s / ±5% or ±0.02µGy/s

• Exposure time: 0.2ms-999.9s

• Fast half value layer: 1.3-10mmAl / ±10% or 0.2mm

• Total filtration: 1.5-30 mm Al / ±10% or ±0.3mm (60-120kV.HF/DC)

Breast machine range and accuracy

• Kilovolts: 20-49 kV / ±1.5% or 0.7 kV

• Dose: 50nGy-50Gy

• Dose rate: 0.4µGy/s-700mGy/s

• Exposure time: 0.2ms-999.9s

• Fast half-value layer: 0.2-1.2 mm Al depending on radiation quality / ±5%

• Total filtration: 1.5-30 mm Al / ±10% or ±0.3mm (60-120kV.HF/DC)

Range and accuracy of CT machine part

• Analysis software can automatically report CTDI value after measurement

• Exposure dose: 10nGy – 9999mGy

• Exposure rate: 100nGy/s – 120mGy/s

• Exposure time: 1 ms – 199999 s

• Effective measuring volume: 4.9cm3

• Overall effective length: 100 mm

• Leakage Rays: < +/-4x10 -15A

• Measuring range: 100 kV – 150 kV

• Scale factor (typ.): ND,K=70mGy*cm/nC(120kV/HWD4.05 mm Al)

Get in Touch With Us

Experienced service team and strong production support team provide client worry-free order service.

    Need help? Contact us.

    If you are interested in any of our products or would like to discuss a customized order, Please feel free to contact us.

    Contact Us